| Home » Products » Stability Chamber » Stability Chamber - PC Interface |
| Stability Chamber - PC Interface : |
- Double walled in construction, gap between the two walls filled with high density Polyurethane Foam (PUF).
- Full-length inner Acrylic door and outside metal door with S.S. lock & keys.
- Food Grade Silicon Gasket fitted on the Chamber and Magnetic Gasket fitted on outer metal door ensures zero leakage between the door & the Chamber.
- Microprocessor based PID controller with direct display of Set & Process Values of Temperature & Humidity. In the event of power failure, Non-Volatile memory allows chamber to return to original set point when power is restored. Unit consists of main switch, fuse, and pilot lamps for all controls.
- Incorporated with Factory certified IMPORTED ROTRONIC AG [SWITZERLAND] make Humidity Sensor for greater Accuracy.
- Forced air circulation for uniform temperature. Cooling by hermetically sealed compressors utilizing R-134A an eco-friendly refrigerant coupled with evaporation coil and condenser, safeguarded by time delay circuit.
- Redundant high temperature safety system automatically cuts-off power to heaters if temperature exceeds 70o c
- Provided with castor wheels for easy moveability.
- Electrically operated on 230 V AC, 50 Hz.
|
|
| TEMPERATURE RANGE |
: 10°c to 60°c |
| TEMPERATURE ACCURACY |
: ± 0.1°c |
| TEMPERATURE UNIFORMITY |
: ± 0.5°c |
| HUMIDITY RANGE |
: 40% to 95% RH |
| HUMIDITY ACCURACY |
: ± 2% RH |
| HUMIDITY UNIFORMITY |
: ± 3% RH |
|
|
| |
| |
| Standard Model - HIPL- 015 : |
- Outer chamber made of Mild Steel [ 20 swg.] duly powder coated and inner chamber made of Stainless Steel LM-304 grade [ 20 swg.] Mirror finish.
- DIGITAL High Temperature Safety Cut off provided.
- Rod type Shelves provided are made of Stainless Steel.
|
| |
| Capacity |
Internal Dimension
W X D X H [cms] |
External Dimension
W X D X H [cms] |
Shelves |
| 4 Cu.Ft. [120 Ltrs] |
45 x 45 x 60 |
64 x 97 x 140 |
02 |
| 6 Cu.Ft. [165 Ltrs] |
50 x 50 x 70 |
69 x 102 x 150 |
02 |
| 10 Cu.Ft. [ 280 Ltrs] |
55 x55 x 90 |
74 x 107 x 170 |
03 |
| 12 Cu.Ft. [ 324 Ltrs] |
60 x 60 x 90 |
79 x 112 x 170 |
03 |
| 16 Cu.Ft. [ 440 Ltrs] |
60 x 60 x 125 |
79 x 112 x 205 |
04 |
| 29 Cu.Ft. [ 800 Ltrs] |
80 x 80 x 125 |
99 x 132 x 205 |
05 |
|
| |
| Optionals : |
- Microprocessor based PROGRAMMABLE PID Controller cum Indicator with Printer Interface to connect Dot Matrix Printer. Print interval programme can print Date, Time, Temperature & Humidity With print interval settable between 1 to 99 minutes [ without Printer ]
- Same as above but with PC software & connectivity
- Fully Automatic Standby Refrigeration System
- Fully Automatic Standby Humidity System
|
| NOTE : Use of a Voltage Stabilizer is strongly recommended for Environmental Test Chambers and is a pre-condition for free service during warranty period. |
| |
|
| |